Effects of Element Directivity in Linear-Array Photoacoustic Imaging

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast photoacoustic imaging system based on 320-element linear transducer array.

A fast photoacoustic (PA) imaging system, based on a 320-transducer linear array, was developed and tested on a tissue phantom. To reconstruct a test tomographic image, 64 time-domain PA signals were acquired from a tissue phantom with embedded light-absorption targets. A signal acquisition was accomplished by utilizing 11 phase-controlled sub-arrays, each consisting of four transducers. The re...

متن کامل

Deep-penetration photoacoustic array imaging of calcifications.

Calcifications are one of the most important indicators for early breast cancer detection. We explore the feasibility of deep-penetration photoacoustic (PA) imaging of calcifications based on a medical ultrasound array imaging platform. Intralipid and chicken breast phantoms embedded with different-sized hydroxyapatite (HA) particles, which are the major components of calcifications, were image...

متن کامل

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Three-dimensional endoscopic photoacoustic imaging based on multielement linear transducer array

An implementation system of three-dimensional endoscopic photoacoustic imaging is presented. The developed endoscopic photoacoustic detector integrates a multielement linear transducer array, a reflective device, a Plexiglass tube, and ultrasonic coupling medium. To match with the acoustic impendence of Plexiglass tube, a glycerin solution with 45% volume percentage was used as the ultrasonic c...

متن کامل

Frequency response and directivity of highly sensitive optical microresonator detectors for photoacoustic imaging

Plano-convex optical microresonator detectors have been developed as an alternative to planar Fabry-Pérot (FP) sensors used in all-optical photoacoustic imaging systems with the potential to provide two or more orders-of-magnitude higher detection sensitivity. This study further characterises the performance of these detectors by investigating their normal incidence frequency response and frequ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Archives in Biomedical Engineering & Biotechnology

سال: 2018

ISSN: 2687-8100

DOI: 10.33552/abeb.2018.01.000504