Effects of pulse pressure alterations on cardiac output measurements derived from analysis of arterial pressure waveform

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices

INTRODUCTION We compared the ability of two devices estimating cardiac output from arterial pressure-curve analysis to track the changes in cardiac output measured with transpulmonary thermodilution induced by volume expansion and norepinephrine in sepsis patients. METHODS In 80 patients with septic circulatory failure, we administered volume expansion (40 patients) or introduced/increased no...

متن کامل

Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy.

BACKGROUND Arterial pressure waveform analysis of cardiac output (APCO) without external calibration (FloTrac/Vigileo™) is critically dependent upon computation of vascular tone that has necessitated several refinements of the underlying software algorithms. We hypothesized that changes in vascular tone induced by high-dose vasopressor therapy affect the accuracy of APCO measurements independen...

متن کامل

Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation.

UNLABELLED The FloTrac/Vigileo™, introduced in 2005, uses arterial pressure waveform analysis to calculate cardiac output (CO) and stroke volume variation (SVV) without external calibration. The aim of this systematic review is to evaluate the performance of the system. Sixty-five full manuscripts on validation of CO measurements in humans, published in English, were retrieved; these included 2...

متن کامل

Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb.

We have developed a new pulse contour cardiac output (PulseCO) algorithm based on frequency analysis studies of the arterial system. PulseCO was compared with thermodilution cardiac output (TDCO) in 10 patients undergoing cardiac surgery. Results from one patient were unsuitable for analysis. In the remaining nine patients, 142 TDCO determinations were compared with PulseCO after logarithmic tr...

متن کامل

The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients

BACKGROUND A relatively new uncalibrated arterial pressure waveform cardiac output (CO) measurement technique is the Pulsioflex-ProAQT® system. Aim of this study was to validate this system in cardiac surgery patients with a specific focus on the evaluation of a difference in the radial versus the femoral arterial access, the value of the auto-calibration modus and the ability to show fluid-ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anesthesia and Pain Medicine

سال: 2016

ISSN: 2383-7977,1975-5171

DOI: 10.17085/apm.2016.11.3.280