Effects of timing of low-intensity pulsed ultrasound on distraction osteogenesis
نویسندگان
چکیده
منابع مشابه
Low-intensity pulsed ultrasound accelerates bone maturation in distraction osteogenesis in rabbits.
We investigated the effects of low-intensity pulsed ultrasound on distraction osteogenesis in a rabbit model. Callotasis of the right tibia was performed in 70 male Japanese white rabbits using mini-external fixators. In the first part of the study in 64 animals using normal distraction (waiting period seven days; distraction rate 0.5 mm/12 hours; distraction period ten days), we evaluated the ...
متن کاملThe effects of low-intensity pulsed ultrasound on fresh fracture
BACKGROUND Low-intensity pulsed ultrasonography (LIPUS) is a form of mechanical stimulation that is delivered via a special device to the fracture site for the acceleration of fracture healing. We conducted a meta-analysis to assess the effect of LIPUS for fresh fractures in adults. METHODS MEDLINE, EMBASE and the Cochrane Library searched between Jan 1980 and Nov 2016. Studies should be quas...
متن کاملEffects of low-intensity pulsed ultrasound on injured skeletal muscle.
BACKGROUND Low-intensity pulsed ultrasound (LIPUS) has been shown to stimulate tissue metabolism and accelerate muscle healing. However, the optimal parameters in the use of LIPUS are still not clear. OBJECTIVE The aim of this study was to analyze the effects of LIPUS on muscle healing in rats subjected to a cryolesion. METHOD Twenty rats were divided into the following groups: an injured c...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملLow Intensity Pulsed Ultrasound (LIPUS)
The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...