EIASTIC BUCKLING OF COOLING TOWERS DUE TO AXISYMMETRIC LOADS

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Stresses in a Linear Plastic FGM Hollow Cylinder Due to Non-Axisymmetric Loads

In this paper, an analytical solution for computing the linear plastic stresses and critical pressure in a FGM hollow cylinder under the internal pressure due to non-Axisymmetric Loads is developed. It has been assumed that the modulus of elasticity was varying through thickness of the FGM material according to a power law relationship. The Poisson's ratio was considered constant throughout the...

متن کامل

Mechanical and Thermal Stresses In a Linear Plastic FGM Hollow Cylinder Due to Axisymmetric Loads

In this paper, an analytical solution for computing the linear plastic stresses and critical temperature and pressure in a FGM hollow cylinder under the internal pressure and temperature is developed. It has been assumed that the modulus of elasticity and thermal coefficient of expansion were varying through thickness of the FGM material according to a power law relationship. The Poisson's rati...

متن کامل

Mechanical and Thermal Stresses in a FGPM Hollow Cylinder Due to Non-Axisymmetric Loads

In this paper, the general solution of steady-state two-dimensional non-axisymmetric mechanical and thermal stresses and mechanical displacements of a hollow thick cylinder made of fluid-saturated functionally graded porous material (FGPM) is presented. The general form of thermal and mechanical boundary conditions is considered on the inside and outside surfaces. A direct method is used to sol...

متن کامل

MINLP Optimization of Cooling Towers

This paper presents a mixed-integer nonlinear programming (MINLP) model for the optimal design of mechanical counter-flow cooling towers, subjected to standard design constraints. The objective function consists of the minimization of the total annual cost, which includes the capital cost of the cooling tower (that depends on the filling material and the air flowrate) and the operating cost (th...

متن کامل

effect of stiffening rings on buckling stability of r.c. hyperbolic cooling towers

design and construction of efficient and economic reinforced concrete (r.c.) hyperbolic cooling towers have driven the engineers toward the design of tall and thin-shell towers which have considerable high slenderness aspect ratio. consequently, the shell of r.c. cooling towers with relative high slenderness aspect ratio is extremely prone to buckling instability due to wind loading. to increas...