Electrochemical membrane microactuator with a millisecond response time
نویسندگان
چکیده
منابع مشابه
Multispectral imaging microscope with millisecond time resolution.
A new multispectral imaging microscope with micrometer spatial resolution and millisecond temporal resolution has been developed. The imaging microscope is based on the use of an acousto-optic tunable filter (AOTF) for spectral tuning and a progressive scan camera capable of snapshot operation for recording. It can operate in two modes: images are recorded as a function of time or wavelength. W...
متن کاملNovel Membrane-Based Electrochemical Sensor for Real-Time Bio-Applications
This article presents a novel membrane-based sensor for real-time electrochemical investigations of cellular- or tissue cultures. The membrane sensor enables recording of electrical signals from a cell culture without any signal dilution, thus avoiding loss of sensitivity. Moreover, the porosity of the membrane provides optimal culturing conditions similar to existing culturing techniques allow...
متن کاملSub-Millisecond Response Time in a Photorefractive Composite Operating under CW Conditions
Extensive study of photorefractive polymeric composites photosensitized with semiconductor nanocrystals has yielded data indicating that the inclusion of such nanocrystals enhances the charge-carrier mobility, and subsequently leads to a reduction in the photorefractive response time. Unfortunately, the included nanocrystals may also act as a source of deep traps, resulting in diminished diffra...
متن کاملA Water-Powered Osmotic Microactuator
This paper presents a microactuator that utilizes osmosis to produce mechanical actuation without consuming any electrical energy. The microactuator is made of cellulose acetate with cylindrical chamber of 500 to 2000 m in diameter and of 200 to 1000 m in depth. Sodium chloride is chosen as the osmotic driving agent to be placed inside the chamber. A semipermeable diaphragm made of cellulose ac...
متن کاملDynamic Response Analysis of Microflow Electrochemical Sensors with Two Types of Elastic Membrane
The Molecular Electric Transducer (MET), widely applied for vibration measurement, has excellent sensitivity and dynamic response at low frequencies. The elastic membrane in the MET is a significant factor with an obvious effect on the performance of the MET in the low frequency domain and is the focus of this paper. In simulation experiments, the elastic membrane and the reaction cavity of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors and Actuators B: Chemical
سال: 2018
ISSN: 0925-4005
DOI: 10.1016/j.snb.2017.12.159