Pixel detectors for diffraction-limited storage rings
Dramatic advances in synchrotron radiation sources produce ever-brighter beams of X-rays, but those advances can only be used if there is a corresponding improvement in X-ray detectors. With the advent of storage ring sources capable of being diffraction-limited (down to a certain wavelength), advances in detector speed, dynamic range and functionality is required. While many of these improveme...
متن کاملResearch on a Non-destructive Fluidic Storage Control Device
This report describes a non-destructive fluidic memory device with associated fluidic alphanumeric display, developed by Giannini Controls Corporation under contract NAS 12-43 with NASA Electronics Research Center. The device uses the surface tension of a liquid bead in an hour-glassshaped cavity to achieve a bi-stable memory effect which does not require a continuous supply of fluid power. Thu...
متن کاملA ug 2 00 4 Storage rings as detectors for relic gravitational – wave background ?
We argue that storage rings can be used for the detection of low–frequency gravitational–wave background. Proceeding from the measurements by Schin Daté and Noritaka Kumagai (Nucl. Instrum. Meth. A421, 417 (1999)) and Masaru Takao and Taihei Shimada (Proceedings of EPAC 2000, Vienna, 2000, p.1572) of variations of the machine circumference of the SPring–8 storage ring we explain the systematic ...
متن کاملec 2 00 3 Storage rings as detectors for cosmic gravitational – wave background ?
We argue that storage rings can be used for the detection of low–frequency gravitational–wave background. Proceeding from the measurements by Schin Daté and Noritaka Kumagai (Nucl. Instrum. Meth. A421, 417 (1999)) and Masaru Takao and Taihei Shimada (Proceedings of EPAC 2000, Vienna, 2000, p.1572) of variations of the machine circumference of the SPring–8 storage ring we explain the systematic ...
متن کاملStorage Rings.
The design, construction, and performance of a streamer-chamber system for the study of inelastic proton-proton collisions at the CERN ISR are described. The chambers have specially shaped ground electrodes to accommodate the ISR vacuum chamber and to obtain an almost 4r~ solid angle. Problems arising from the non-fiat electrodes and the insertion of converter plates into the sensitive volume o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2017
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/875/10/092014