Electromagnetic transient analysing of neutral bus in UHVDC converter station

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Compact Dynamic Bus Station

This document is one of the parts of the electronic version of the PhD thesis by S F M van Vlijmen The goal of the PhD project was to get a better under standing of the problems with the integration of formal speci cation technique in the day to day software practice The approach followed was to execute a number of projects in cooperation with industry on realistic cases In this document is rep...

متن کامل

External Insulation Design of Converter Stations for Xiangjiaba - Shanghai ± 800 kV UHVDC Project

-External insulation is one of the critical aspects in the HVDC equipments and converter station design. Especially for UHVDC converter stations, the long creepage and clearance required has significant impact on the equipment and station design. The external insulation design of DC yard, valve hall, and for converter valves is presented. It is the intention of this report to review and summari...

متن کامل

Input Power Factor Control of Matrix Converter Based Transmitter for Transient Electromagnetic Sounding

Three-phase to single-phase matrix converter (TSMC) is used as the transmitter for transient electromagnetic method (TEM) instrument, instead of an AC-DC converter and an H-bridge inverter. The transmitter produces excitation current for primary field. The output current has a waveform with a bipolar square of half duty cycle, which is required by TEM. The space vector PWM based on input curren...

متن کامل

Performance Evaluation of UHF RFID Technologies for Real-Time Bus Recognition in the Taipei Bus Station

Transport stations such as airports, ports, and railways have adopted blocked-type pathway management to process and control travel systems in a one-directional manner. However, this excludes highway transportation where large buses have great variability and mobility; thus, an instant influx of numerous buses increases risks and complicates station management. Focusing on Taipei Bus Station, t...

متن کامل

Investigation of Station Service Transformer Ferroresonance in Manitoba Hydro’s 230-kV Dorsey Converter Station

An investigation of ferroresonance in a 230-kV transformer is undertaken. Correct modelling of the iron-core losses and the direct magnetic coupling between phases are shown to be important in duplicating field observations. A brute-force time-domain method and an analytical method for displaying margins to ferroresonance on a parameter plane are compared. Following proposed bus modifications, ...

متن کامل