Electron transit time measurements of 5-in photomultiplier tubes
نویسندگان
چکیده
منابع مشابه
Photomultiplier Tubes
Light which enters a photomultiplier tube is detected and produces an output signal through the following processes. (1) Light passes through the input window. (2) Light excites the electrons in the photocathode so that photoelectrons are emitted into the vacuum (external photoelectric effect). (3) Photoelectrons are accelerated and focused by the focusing electrode onto the first dynode where ...
متن کاملPhotomultiplier Tubes
including basic and performance. For example, section 4.1 shows spectral response characteristics of typical photocathodes and also gives the definition of photocathode sensitivity and its measurement procedure. Section 4.2 explains dynode types, structures and typical characteristics. Section 4.3 describes various performance characteristics such as time response, operating stability, sensitiv...
متن کاملImprovement of 20 in. diameter photomultiplier tubes
The quality of the 20 in . photomultiplier tubes (Hamamatsu R1449) has been greatly improved over the required specifications for using them m the 50000 ton imaging water Cherenkov detector, Super-Kamiokande . In particular, the resolution of the timing response for single-photoelectron light has been reduced to 3 ns (1Q width), and a clear single-photoelectron peak can be seen in the pulse hei...
متن کاملInvestigation and compensation of the nonlinear response in photomultiplier tubes for quantitative single-shot measurements.
A concept for time-sensitive optical detectors is described that shows how to confirm whether the detection device is operating in the linear response regime. By evaluating the recorded time decay of a thermographic phosphor, even weak saturation effects far from obvious situations can be identified and further related to either optical or electrical saturation. The concept has been validated b...
متن کاملOne-Way Transit Time Measurements
The main goals of the technical report are towards an understanding of the delay process in best-effort Internet for both non-congested and congested networks. A dedicated measurement system is reported for delay measurements in IP routers, which follows specifications of the IETF RFC 2679. The system is using both passive measurements and active probing. Dedicated application-layer software is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2016
ISSN: 0168-9002
DOI: 10.1016/j.nima.2016.05.024