Elimination of tall building vibration resulting from ground motions
نویسندگان
چکیده
منابع مشابه
TOPOLOGY OPTIMIZATION OF 2D BUILDING FRAMES UNDER ARTIFICIAL EARTHQUAKE GROUND MOTIONS USING POLYGONAL FINITE ELEMENT METHOD
In this article, topology optimization of two-dimensional (2D) building frames subjected to seismic loading is performed using the polygonal finite element method. Artificial ground motion accelerograms compatible with the design response spectrum of ASCE 7-16 are generated for the response history dynamic analysis needed in the optimization. The mean compliance of structure is minimized as a t...
متن کاملWavelet-based Analysis for Pulse Period of Earthquake Ground-motions
Pulse period of earthquake records has been known as a key parameter in seismology and earthquake engineering. This paper presents a detailed characterization of this parameter for a special class of earthquake records called pulse-like ground motions. This type of motions often resulting from directivity effects is characterized by a strong pulse in the velocity time history of motion, in norm...
متن کاملMeasurement of ground-to-building frequency response functions for assessment of human exposure to vibration from railway vibration
The University of Salford has derived exposure-response relationships for vibration caused by railway construction and operation in residential environments. The exposure assessment methodology for almost 1000 case studies has its key factor in the measurement of synchronized ground-to-building frequency response functions (FRF). The latter is obtained by averaging the spectral content of simul...
متن کاملIsolation of Performance Halls from Ground Vibration
One of the inherent characteristics of transportation systems, especially steel wheel and rail systems, is that vehicles running on the roadway or trackway generate vibration which transmits through the ground into nearby buildings. As our urban areas build up or are redeveloped, it is frequently desired for a variety of reasons to place a concert hall or theater in a location which is in close...
متن کاملelimination of btex , voc vapors from glycol in gas hydrant unit
during natural gas processing, water in natural gas may cause to hydrates formation in pipelines which may lead to serious damages to process equipments. given the problems raised by present of water in natural gas, glycol solvent uses to remove water.in contact of glycol with gas always an amount of btex and voc absorb along with water, which on glycol recovery process, these substances separa...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PAMM
سال: 2008
ISSN: 1617-7061
DOI: 10.1002/pamm.200810897