Elliptical Subject Specific model for respiratory motion
نویسندگان
چکیده
منابع مشابه
Elliptical Subject Specific model for respiratory motion
Background Respiratory motion of the heart poses a problem for high resolution cardiac MR imaging. Prospective slice following uses the navigator position immediately prior to the imaging segment to correct the slice positions throughout the segment [1]. The navigator is typically placed over the right hemi-diaphragm and a fixed correction factor is used to adjust for the difference to the moti...
متن کاملA fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study
Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...
متن کاملA subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures
We describe a system for respiratory motion correction of MRI-derived roadmaps for use in X-ray guided cardiac catheterisation procedures. The technique uses a subject-specific affine motion model that is quickly constructed from a short pre-procedure MRI scan. We test a dynamic MRI sequence that acquires a small number of high resolution slices, rather than a single low resolution volume. Addi...
متن کاملMotion Estimation Model for Cardiac and Respiratory Motion Compensation
Catheter ablation is widely accepted as the best remaining option for the treatment of atrial fibrillation if drug therapy fails. Ablation procedures can be guided by 3-D overlay images projected onto live fluoroscopic X-ray images. These overlay images are generated from either MR, CT or C-Arm CT volumes. As the alignment of the overlay is often compromised by cardiac and respiratory motion, m...
متن کاملa fast model for prediction of respiratory lung motion for image-guided radiotherapy: a feasibility study
background: the aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one ct dataset. materials and methods: for each of six patients with different thorax sizes, two sets of ct images were obtained in single-breath-hold inhale and exhale stages in the supine position. the ct images were then analyzed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance
سال: 2012
ISSN: 1532-429X
DOI: 10.1186/1532-429x-14-s1-p267