Embankment dam seepage evaluation from resistivity monitoring data

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Embankment dam spillways and energy dissipators

For the last fifty years, the design floods of a number of embankment dams were re-evaluated and the revised spillway outflows are often larger than the original design discharges. Several embankment overtopping protection systems were developed for earthfill structures, and the applications range from river dykes to tsunami protections including embankment dams. Well-known designs include timb...

متن کامل

Forecasting embankment dam behaviour with artificial intelligence

Forecasting dam behaviour is of paramount importance to avoid collapses. It consists of detecting and controlling deterioration mechanisms. This paper sets out to propose a multi model methodology to model complex dynamic systems, such as dams. It defines three models based on expert knowledge: a structural model, a functional model and a behavioural model. They are developed from the stories o...

متن کامل

Seismic Behavior of Zoned Core Embankment Dam

The aim of this investigation is to study the dynamic behavior of a zoned core earth-fill dam. Due to lack of suitable clay materials, the Mamloo dam is designed as zoned core that is composed of three vertical zones including central lean clay (CL) core and two sides clayey gravel (GC) layers. Seismic behavior of dam was analyzed in two cases including homogenous clayey core and zoned core by ...

متن کامل

Energy Dissipation and Residual Energy on Embankment Dam Stepped Spillways

Stepped spillways are designed to increase the rate of energy dissipation on the chute and to reduce the size of the downstream energy dissipator. It is essential to predict accurately the turbulent dissipation above the steps for large discharges per unit width corresponding to the skimming flow regime. New measurements were conducted in a large facility with a channel slope of 21.8o and a ste...

متن کامل

Subsurface structural characterization of the Chooman Dam site using geoelectric method

A recent evaluation of Chooman Dam highlighted the potential for dam failure due to either seepage or an earthquake on nearby faults. Unfortunately, this dam suffers from infiltration or leakage problems related mainly to different geological and tectonic factors. In response to these concerns, electrical resistivity surveys employing vertical electric sounding (VES) method were carried out at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Near Surface Geophysics

سال: 2009

ISSN: 1569-4445,1873-0604

DOI: 10.3997/1873-0604.2009023