This paper is focused on the input current in a Switched Mode Power Supply (SMPS) which power inductor exploited up to saturation showing non-linear behaviour. The exhibits distortion due nonlinearity. electromagnetic interference (EMI) caused by ripple at switching frequency, superimposed DC value of current, requires suitable design differential mode (DM) filter. analyzed both time and frequency domain for different operating conditions, it compared SMPS equipped with traditional linear inductor.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-linear inductor SPICE simulation

The main folder (name: non-linear inductor) includes four subfolders (Buck, Buck_Average, Behavior and Param_Mod), each folder contains one simulation project for the corresponding simulation circuit. The inductor data refers to a 77254A7 iron powder core (Kool Mu) characteristics, drawn from MAGNETICS data sheets. Technical data: http://www.mag-inc.com/pdf/MAGNETICS_Powder_Core_Technical_Data....

متن کامل

a new type-ii fuzzy logic based controller for non-linear dynamical systems with application to 3-psp parallel robot

abstract type-ii fuzzy logic has shown its superiority over traditional fuzzy logic when dealing with uncertainty. type-ii fuzzy logic controllers are however newer and more promising approaches that have been recently applied to various fields due to their significant contribution especially when the noise (as an important instance of uncertainty) emerges. during the design of type- i fuz...

15 صفحه اول

Mixed Mode EMI Noise Level Measurement in SMPS

Fast switching in SMPS generate large amount of Electromagnetic Interference (EMI).The proposed method to determine Common Mode (CM) and Differential Mode (DM) noise of a low power Switched Mode Power Supply (SMPS) using two-probe approach i.e. using one current probe as an injecting probe and other current probe as receiving probe Common Mode (CM) noise is measured between power line and groun...

متن کامل

Emi-induced Failures in Pwm Controllers for Smps

this paper describes the last achievements on the susceptibility to RF interference (RFI) of smart power system on chip. To this purpose, a PWM voltage-mode switching mode power supply (SMPS) has been designed (including the control unit) and a complete analysis about RFI effects on the control circuit operation has been carried out by computer simulations. In particular, it is pointed out that...

متن کامل

non-linear study of various slit shear walls in steel structures

seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...

15 صفحه اول