Enabling Closed-Loop Surgery in MRI

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anesthesia in Cardiac Surgery (Open-Closed Heart)

In this paper the duties of an anesthesiologist and his right of i=;electing patient is discussed. La,ter, we di:=:cuss the <::mergencies cf heart surgery, pre up visit and alsc few dcails of pre up medication cf thei,e pati<mts. We also touch on the stages of anesthPsia and point to our preference for the use cf artery and vein for arterial and venous cannulation. In this paper we discuss in b...

متن کامل

Closed-loop Position Control of an MRI-powered Biopsy Robot

INTRODUCTION Clinical MRI scanners can provide large amounts of electromagnetic energy that potentially could be used for actuation as well as imaging and so provide a complete environment for robotic interventions. The idea of using MR scanner magnetic gradients for actuating and tracking millimeter or micrometer size ferromagnetic particles was initially proposed and performed by Martel et al...

متن کامل

A Closed-loop MRI-powered Actuator for Robotic Interventions

Introduction Robotically-assisted MR-guided interventions are becoming increasingly important in the clinical community. Surgical robots offer precision, accuracy, speed, and the potential for remote operation, while the MRI offers superior soft tissue contrast and a well-defined 3D coordinate system. The synergy of both systems results in robotically assisted MR-guided interventional procedure...

متن کامل

Distance protection closed-loop testing using RTDS

This paper presents a distance protection test procedure by applying the Real-Time Digital Simulator (RTDS) of a power system. RTDS is a tool to design, develop, and test power-system protection. The RTDS enables real-time computation of electromagnetic phenomena with a calculation time step of even 50μs. The hardware allows the import and export of many signals from the simulator to an ext...

متن کامل

THD Analysis in Closed-Loop Analog PWM Class-D Amplifiers

In this paper, we investigate the parameters affecting Total Harmonic Distortion (THD) and Power Supply Rejection Ratio (PSRR) in PWM Class D Amplifiers (CDAs) on the basis of linear models with feedback. From our mathematical analysis, we show that the THD of a PWM Class D amplifier with feedback can be improved by increasing the gain of the integrator through adding another amplifier at the o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Mechanical Engineering

سال: 2015

ISSN: 0025-6501,1943-5649

DOI: 10.1115/1.2015-sep-8