Enantiomer separation of small amounts of amino acids and hydroxy acids by HPLC using chiral stationary phases and achiral derivatizing reagents.
نویسندگان
چکیده
منابع مشابه
Performance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids
The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...
متن کاملBonded peptide stationary phases for the separation of amino acids and peptides using liquid chromatography.
Bonded optically active tripeptides have been applied as stationary phases for liquid chromatography. Significant retention variations are shown for some UV absorbing amino acids when compared to a silica gel column using the same mobile phase. The separation of certain isomeric dipeptides has been accomplished using the bonded optically active tripeptide stationary phases. It is shown that th...
متن کاملEnantiomer separation of mandelates and their analogs on cyclodextrin derivative chiral stationary phases by capillary GC.
Enantiomer separation of mandelates and their analogs, which are important intermediates in asymmetric synthetic and pharmaceutical chemistry, was investigated by capillary gas chromatography using different cyclodextrin derivative chiral stationary phases (CD CSPs). The used cyclodextrin derivatives included permethylated beta-CD (PMBCD), permethylated gamma-CD, heptakis(2,6-di-O-butyl-3-O-but...
متن کاملComparative Gas Chromatography of Halides Using Different Substituted Phenylboronic Acids as Derivatizing Reagents
The GC of halides (chloride, bromide and iodide) using phenylboronic acid (PBA), 4-bromophenylboronic acid (BPBA), 3, 5 bis (trifluoromethyl) phenylboronic acid (FPBA) and 2,4- dichlorophenylboronic acid (CPBA) as derivatizing reagents are compared. The reactions are carried out in the presence of mercuric salts. The detection systems used are FID and ECD. The thermal analysis of the compou...
متن کاملSeparation of Racemic Mixtures of Amino Acids Using Chiral Eluents
A commercially available non-chiral RP-C8 chromatographic column is used with an aqueous chiral mobile phase containing N,N-dimethyl-L-phenylalanine and copper in a ratio 20 : 1 for the enantiomeric resolution of the following amino acids: DL-valine (Val), DL-methionine (Met), DL-leucine (Leu), DL-phenylalanine (Phe) and DL-tyrosine (Tyr). The influence of organic modifier, temperature and flow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1995
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.44.301