End Effects in Thermal Diffusivity Measurements
نویسندگان
چکیده
منابع مشابه
Diffusivity Measurements of Human Methemoglobin
Experimental measurements of the diffusion coefficient of human methemoglobin were made at 25 degrees C with a modified Stokes diaphragm diffusion cell. A Millipore filter was used in place of the ordinary fritted disc to facilitate rapid achievement of steady state in the diaphragm. Methemoglobin concentrations varied from approximately 5 g/100 ml to 30 g/100 ml. The diffusion coefficient in t...
متن کاملAccurate measurements of the thermal diffusivity of thin films and thin filaments using lock-in thermography
In lock-in thermography the thermal diffusivity can be obtained from the slope of the linear relation between the phase of the surface temperature and the distance to the heating spot. However, in the case of thin samples, the linearity is not found. In this work we identify heat conduction to the surrounding gas as the mechanism responsible for the lost of linearity. Accordingly accurate measu...
متن کاملGauging colloidal and thermal stability in human IgG1-sugar solutions through diffusivity measurements.
Monoclonal antibodies are the fastest growing class of biotherapeutics. Ensuring their colloidal and conformational stability in liquid dispersions is crucial for maintaining therapeutic efficacy and economic viability. Sugars are often added to increase the colloidal and thermal stability of protein; however, determining which sugar is the most stabilizing requires time and sample-consuming st...
متن کاملLocal measurements of thermal diffusivity in homogeneous and heterogeneous samples by photoreflectance microscopy
We present a variant of the traditional photoreflectance microscopy. It allows thermal diffusivity measurements on samples as small as a few tens of microns, possibly of mediocre surface quality. In "photoreflectance microscopy", the sample is heated by a modulated laser beam focused by a microscope. A dc probe beam of lower intensity, also focused on the sample by the microscope, is reflected ...
متن کاملA Parameter Estimation Procedure in Thermal Diffusivity Measurements Using the Laser Flash Method
Paper presents the application of Gauss estimation procedure in measuring thermal diffusivity of single materials using the laser pulse method. Unlike procedures, based on that originally established by Parker et al., where thermal diffusivity is derived using one or more characteristic points of experimental signal, this one belongs to socalled inverse technique, which makes use of complete me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemical engineering
سال: 1965
ISSN: 0375-9253
DOI: 10.1252/kakoronbunshu1953.29.974