Endocardial pacing electrode design and rate of displacement.
نویسندگان
چکیده
منابع مشابه
Pericardial complications of endocardial and epicardial pacing.
A patient with complete atrioventricular block was fitted with a temporary endocardial pacing wire via a right subclavian percutaneous approach. The result was initially satisfactory, but within a few days radiography for left-sided chest pain showed pneumopericardium. A permanent epicardial pacing system was therefore substituted and she remained well for three months. She was then admitted fo...
متن کاملEndocardial fibrosis. Detection by cardiac pacing.
ENDOCARDIAL FIBROSIS occurs in diverse diseases. An infantile form appears to reflect an unexplained congenital derangement in which a thick layer of collagen and elastin lines the left ventricular cavity.' Sporadic instances noted in the adolescent have also been presumed to be of congenital origin.2 A poorly understood cause of heart failure occurs frequently in Uganda and South Africa in ass...
متن کامل'… And now what to do?' Direct surgical trans-atrial endocardial pacing electrode implantation in a very complex situation.
Andrea Rossi1*, Alberto Clemente2, Dante Chiappino2, Michele Emdin1, and Marcello Piacenti1 Invasive Cardiology Division, Arrhythmology Division, Fondazione Gabriele Monasterio CNR-Regione Toscana, via Giuseppe Moruzzi, Pisa 56124, Italy; and Radiology Division, Fondazione Gabriele Monasterio CNR-Regione Toscana, Pisa, Italy * Corresponding author. Tel: +39 0503153219. E-mail address: andrea.ro...
متن کاملTargeted left ventricular endocardial pacing using a steerable introducing guide catheter and active fixation pacing lead.
AIMS Cardiac resynchronization therapy via the coronary sinus (CS) is not always possible. Left ventricular (LV) endocardial lead placement is a potential alternative. The purpose of this study was to assess the feasibility of endocardial LV pacing using a steerable lead introducer and active fixation polyurethane lead. METHODS AND RESULTS Endocardial LV lead placement was attempted in nine p...
متن کاملUnusual fracture of cardiac pacing electrode.
This report describes a patient with an epicardial demand pacing system in whom pacing failure two months after implantation was found to be due to a fracture of the helical wire electrode within its supporting structure. We know of no report of this site of failure of a Cordis 323-451 or similar electrode.