Energy-resolved computed tomography with a response-function-less transXend detector

نویسندگان

چکیده

A ‘transXend’ detector measures X-rays as electric current and yields an X-ray energy spectrum after analysis. Response functions are necessary for the analysis previously estimated using m...

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Material Decomposition Using Ensemble Learning for Energy-Resolved Computed Tomography

Material decomposition facilitates the differentiation of different materials in X-ray imaging. As an alternative to the previous empirical material decomposition methods, we performed material decomposition using ensemble learning methods in this work. Three representative ensemble methods with two decision trees as the base learning algorithms were implemented to perform material decompositio...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Spectral Computed Tomography with a Photon-Counting Silicon-Strip Detector

Computed tomography (CT) is a widely used medical imaging modality. By rotating an x-ray tube and an x-ray detector around the patient, a CT scanner is able to measure the x-ray transmission from all directions and form an image of the patient’s interior. CT scanners in clinical use today all use energy-integrating detectors, which measure the total incident energy for each measurement interval...

متن کامل

Characterization and Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral Computed Tomography

Multibin photon-counting x-ray detectors are promising candidates to be applied in next generation computed tomography (CT), whereby energy information from a broad x-ray spectrum can be extracted and properly used for improving image quality and correspondingly reducing radiation dose. A silicon-strip detector has been developed for spectral CT, which operates in photon-counting mode and allow...

متن کامل

A multi detector computed tomography survey of tracheal diverticulum.

OBJECTIVE Tracheal diverticulum (DV) is an incidental finding in thoracic computed tomography examinations. Tracheal DV may be associated with chronic cough and chronic obstructive pulmonary disease (COPD). A few studies have investigated the relationship between tracheal DV and COPD. There is still no consensus on the relationship. The purpose of this study was to determine the incidence of tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Nuclear Science and Technology

سال: 2021

ISSN: ['0022-3131', '1881-1248']