Energy-saving analysis of ground source heat pump combined with floor radiant air conditioning system
نویسندگان
چکیده
منابع مشابه
Determining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations
One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...
متن کاملAssessment and Deployment of Ground Source Heat Pump for Air Pollution Reduction in Tehran, Iran
The use of renewable energies, especially in metropolises has led to a reduction in environmental pollution and greater access to clean, renewable and sustainable energy. This paper evaluates the effectiveness of a national plan adopted by the Tehran city council for reducing air pollutions. This plan is designed to increase the share of renewable energies in residential buildings. This study a...
متن کاملPerformance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System
This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملEnhancements of an Integrated Simulation Tool for Ground- Source Heat Pump System Design and Energy Analysis
Ground-source heat pump (GSHP) utilizes the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. GSHP systems are generally comprised of water source heat pumps and ground heat exchangers (GHX). Vertical closed-loop GHX is used predominantly in commercial and institutional applications. Closed loop GHX consists of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Procedia Engineering
سال: 2017
ISSN: 1877-7058
DOI: 10.1016/j.proeng.2017.09.896