ENHANCEMENT OF MPPT MODULE FOR PARTIAL SHADING PHOTOVOLTAIC SYSTEM UNDER UNIFORM IRRADIANCE CONDITIONS

نویسندگان

چکیده

Maximum Power Point Tracking (MPPT) algorithms play a critical role in maximizing the output power of solar panels. Different MPPT techniques are evaluated based on several criteria, such as tracking speed, simplicity, and accuracy with changes irradiance ambient temperature. Under partial shading conditions (PSCs), conventional fail to track global maximum points (GMPP). This paper aims present an automatic accurate method fix complexity determining lookup table data fast process under uniform (UICs) PSCs. The proposed runs photovoltaic (PV) module all potential It automatically calculates perfect voltage reference (Vref) for PV system cases. Vref is collected array, sent into two-dimensional table, used controlling boost converter. Simulation results verify effectiveness method. In addition, comparison was also made perturb observe (P&O) UICs, takes less time than P&O algorithm reach MPP. difference between them ?t = 0.133 sec 0.04 first scanning at t 0 sudden change 1.5 sec, respectively. As PSCs, reached GMPP during pattern 104 (first peak) without any loss, while able but losses 2729.97 watts. ABSTRAK: Algoritma Penjejakan Titik Kuasa Maksimum memainkan peranan penting dalam memaksimumkan kuasa keluaran panel solar. Teknik yang berbeza dinilai berdasarkan beberapa kriteria seperti kelajuan pengesanan, kesederhanaan, dan ketepatan dengan perubahan sinaran suria suhu ambien. Di bawah keadaan teduhan separa (PSC), teknik konvensional gagal menjejak titik maksimum Kajian ini bertujuan bagi membentangkan kaedah automatik tepat membetulkan kesusahan menentukan carian berjadual secara tepat, pantas di seragam (UIC) PSC. Kaedah dicadangkan menjalankan modul fotovoltaik semua potensi mengira rujukan voltan sempurna kes berpotensi sebarang jenis sistem PV. dikumpul tata susunan, dihantar ke jadual dua dimensi, digunakan mengawal penukar rangsangan. Keputusan simulasi mengesahkan keberkesanan dicadangkan. Perbandingan juga dibuat perhati ganggu (P&O). UIC, mengambil masa lebih singkat berbanding algoritma mencapai Perbezaan antara keduanya adalah masing-masing, saat proses pengimbasan pertama iaitu pada mendadak saat. Bagi PSC, semasa corak (puncak pertama) tanpa kehilangan manakala dapat mengesan tetapi pengurangan sebanyak watt.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photovoltaic Array Modeling under Uniform Irradiation and Partial Shading Condition

Received Sep 9, 2017 Revised Oct 28, 2017 Accepted Nov 15, 2017 Wind energy and solar energy are the prime energy sources which are being utilized for renewal energy. The performance of a photovoltaic (PV) array for solar energy is affected by temperature, irradiation, shading, and array configuration. Often, the PV arrays are shadowed, completely or partially, by the passing clouds, neighborin...

متن کامل

New Strategy of Grid Connected Photovoltaic System Using Module Integrated Converters with B4 Inverter to Overcome Partial Shading Effect

This paper proposes a new configuration for solar energy conversion systems. One challenging issue of the photovoltaic (PV) systems is partial shading, and in this paper Module Integrated Converters (MIC) are used to overcome this problem in PV arrays. A few boost converters are employed as MICs to mitigate the shading effect. Furthermore, to reduce the cost and to increase the system performan...

متن کامل

Anfis Modelling, Partial Shading and Mppt Controlled Hardware Analysis of Stand Alone Photovoltaic Water Pumping System

The solar photovoltaic power has received great attention and experienced impressive progress the countries all over the world in recent years because of more and more serious energy crisis and environmental pollution. Due to scarcity of fossil fuel and increasing demand of power supply, we are forced to utilize the renewable energy resources. Considering easy availability and vast potential, w...

متن کامل

Maximum Power Point Tracker for Photovoltaic Systems Based on Moth-Flame Optimization Considering Partial Shading Conditions

The performance of photovoltaic (PV) systems is highly dependent on environmental conditions. Due to probable changes in environmental conditions, the real-time control of PV systems is essential for exploiting their maximum possible power. This paper proposes a new method to track the maximum power point of PV systems using the moth-flame optimization algorithm. In this method, the PV DC-DC co...

متن کامل

Partial Shading Detection and MPPT Controller for Total Cross Tied Photovoltaic using ANFIS

This paper present Maximum Power Point Tracking (MPPT) controller for solving partial shading problems in photovoltaic (PV) systems. It is well-known that partial shading is often encountered in PV system issue with many consequences. In this research, PV array is connected using TCT (total cross-tied) configuration including sensors to measure voltage and currents. The sensors provide inputs f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IIUM Engineering Journal

سال: 2023

ISSN: ['2289-7860', '1511-788X']

DOI: https://doi.org/10.31436/iiumej.v24i2.2752