EP-1241: Dosimetric effects of intra-fractional target motion in TomoTherapy
نویسندگان
چکیده
منابع مشابه
A motion phantom study on helical tomotherapy: the dosimetric impacts of delivery technique and motion.
Helical tomotherapy (HT) can potentially be used for lung cancer treatment including stereotactic radiosurgery because of its advanced image guidance and its ability to deliver highly conformal dose distributions. However, previous theoretical and simulation studies reported that the effect of respiratory motion on statically planned tomotherapy treatments may cause substantial differences betw...
متن کاملA comparison of the dosimetric effects of intrafraction motion on step‐and‐shoot, compensator, and helical tomotherapy‐based IMRT
Intrafraction motion during intensity-modulated radiation therapy can cause differences between the planned and delivered patient dose. The magnitude of these differences is dependent on a number of variables, including the treatment modality. This study was designed to compare the relative susceptibility of plans generated with three different treatment modalities to intrafraction motion. The ...
متن کاملDosimetric accuracy of tomotherapy dose calculation in thorax lesions
BACKGROUND To analyse limits and capabilities in dose calculation of collapsed-cone-convolution (CCC) algorithm implemented in helical tomotherapy (HT) treatment planning system for thorax lesions. METHODS The agreement between measured and calculated dose was verified both in homogeneous (Cheese Phantom) and in a custom-made inhomogeneous phantom. The inhomogeneous phantom was employed to mi...
متن کاملQuantifying intra- and inter-fractional motion in breast radiotherapy
INTRODUCTION The magnitude of intra- and inter-fractional variation in the set up of breast cancer patients treated with tangential megavoltage photon beams was investigated using an electronic portal imaging device (EPID). METHODS Daily cine-EPID images were captured during delivery of the tangential fields for ten breast cancer patients treated in the supine position. Measurements collected...
متن کاملLong‐term dosimetric stability of multiple TomoTherapy delivery systems
The dosimetric stability of six TomoTherapy units was analyzed to investigate changes in performance over time and with system upgrades. Energy and output were tracked using monitor chamber signal, onboard megavoltage computed tomography (MVCT) detector profile, and external ion chamber measurements. The systems (and monitoring periods) include three Hi-Art (67, 61, and 65 mos.), two TomoHDA (3...