EP-1509: Small fields Output Factor measurement using several multidetectors arrays

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

متن کامل

Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions

Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...

متن کامل

Optimisation of output factor measurements using the Magic Plate 512 silicon dosimeter array in small megavoltage photon fields

We evaluate the impact of an air gap and optimization of this air gap for the MP512 silicon detector array when operated in dosimetry mode for small photon field measurements in solid water. We present output factor measurements for 6MV and 10 MV photon beams with the square field sizes ranging from 0.5 to 10 cm2. The size of the air gap above the MP512 detector was changed from 0.5, 1.0, 1.2, ...

متن کامل

Measurement of Cardiac Output using Bioimpedance Methd

Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Cardiac output is the functional expression of cardiovascular performance and can be used to confirm the need for, or usefulness of treatment. Determination of cardiac output is an important procedure in interventional cardiology and also used in cardiothora...

متن کامل

Measurement of Cardiac Output using Bioimpedance Method

Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Cardiac output is the functional expression of cardiovascular performance and can be used to confirm the need for, or usefulness of treatment. Determination of cardiac output is an important procedure in interventional cardiology and also used in cardiothora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2016

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(16)32759-1