EP-1521: Non-coplanar beam orientation and fluence map optimization based on group sparsity

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast non-coplanar beam orientation optimization based on group sparsity

Objective: The selection of beam orientations, which is a key step in radiation treatment planning, is particularly challenging for non-coplanar radiotherapy systems due to the large number of candidate beams. In this paper, we report progress on the group sparsity approach to beam orientation optimization, wherein beam angles are selected by solving a large scale fluence map optimization probl...

متن کامل

Neighborhood search approaches to non-coplanar beam orientation optimization for total marrow irradiation using IMRT

We consider the beam orientation optimization (BOO) problem for total marrow irradiation (TMI) treatment planning using intensity modulated radiation therapy (IMRT). Currently, IMRT is not widely used in TMI treatment delivery; furthermore, the effect of using non-coplanar beam orientations is not known. We propose and implement several variations of a single neighborhood search algorithm that ...

متن کامل

Iterative Solution Methods for Beam Angle and Fluence Map Optimization in Intensity Modulated Radiation Therapy Planning

We present computational approaches for optimizing beam angles and fluence maps in Intensity Modulated Radiation Therapy (IMRT) planning. We assume that the number of angles to be used for the treatment is given by the treatment planner. A mixed integer programming (MIP) model and a linear programming (LP) model are used to find an optimal set of beam angles and their corresponding fluence maps...

متن کامل

Beam rate influence on dose distribution and fluence map in IMRT dynamic technique.

AIM To examine the impact of beam rate on dose distribution in IMRT plans and then to evaluate agreement of calculated and measured dose distributions for various beam rate values. BACKGROUND Accelerators used in radiotherapy utilize some beam rate modes which can shorten irradiation time and thus reduce ability of patient movement during a treatment session. This aspect should be considered ...

متن کامل

Beam Angle Optimization for Automated Coplanar IMRT Lung Plans

Beam Angle Optimization for Automated Coplanar IMRT Lung Plans by Kathryn Hedrick Medical Physics Graduate Program Duke University Date:_______________________ Approved: ___________________________ Q. Jackie Wu, Supervisor ___________________________ Jing Cai ___________________________ Anuj Kapadia An abstract of a thesis submitted in partial fulfillment of the requirements for the degree of M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2017

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(17)31956-4