EP-1660: Interfraction Internal Target Volume dose coverage in Stereotactic Body Radiotherapy for infradiafragmatic tumor

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is internal target volume accurate for dose evaluation in lung cancer stereotactic body radiotherapy?

PURPOSE 4DCT delineated internal target volume (ITV) was applied to determine the tumor motion and used as planning target in treatment planning in lung cancer stereotactic body radiotherapy (SBRT). This work is to study the accuracy of using ITV to predict the real target dose in lung cancer SBRT. MATERIALS AND METHODS Both for phantom and patient cases, the ITV and gross tumor volumes (GTVs...

متن کامل

Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiven...

متن کامل

Dose tolerance limits and dose volume histogram evaluation for stereotactic body radiotherapy

Almost 20 years ago, Emami et al. presented a comprehensive set of dose tolerance limits for normal tissue organs to therapeutic radiation, which has proven essential to the field of radiation oncology. The paradigm of stereotactic body radiotherapy (SBRT) has dramatically different dosing schemes but, to date, there has still been no comprehensive set of SBRT normal organ dose tolerance limits...

متن کامل

Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer.

We evaluated the four-dimensional (4D) dose to a moving target by a Monte Carlo dose calculation algorithm in stereotactic body radiation therapy (SBRT) planning based on the isocenter dose prescription. 4D computed tomography scans were performed for 12 consecutive patients who had 14 tumors. The gross tumor volume (GTV) and internal target volume (ITV) were contoured manually, and the plannin...

متن کامل

Safety of high-dose-rate stereotactic body radiotherapy

BACKGROUND AND PURPOSE Flattening filter free (FFF) beams with high dose rate are increasingly used for stereotactic body radiotherapy (SBRT), because they substantially shorten beam-on time. The physical properties of these beams together with potentially unknown radiobiological effects might affect patient safety. Therefore here we analyzed the clinical outcome of our patients. MATERIAL AND...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2015

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(15)41652-4