EP-1709 Dosimetric response of aSi1000 EPID continuous imaging of FFF beams for in vivo 3D SBRT verification

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EPID‐based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams

We proposed to perform a basic dosimetry commissioning on a new imager sys-tem, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter-free (FFF) beams, then to develop an image-based quality assurance (QA) model for verification of the system delivery accuracy for intensity-modulated radiation therapy (IMRT) treat-...

متن کامل

Camera based EPID dosimetric verification of radiation treatments

Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context.   Materials and Methods: In this study, ...

متن کامل

SU-E-T-01: Applications of 6MV FFF Photon Beams in Optimizing Radiobiological Response for Respiratory-Gated Liver SBRT.

PURPOSE To establish a radiobiological basis for gated stereotactic body radiotherapy of primary and metastatic liver cancers using volumetric arc radiotherapy in a flattening filter free (FFF) mode. METHODS Human cervical carcinoma, SiHa, non-small cell lung carcinoma, H460, and Chinese hamster V79 cells were irradiated in a water bath with 6MV photons from a Varian TrueBeam linear accelerat...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

Dosimetric IMRT verification with a flat-panel EPID.

A convolution-based calibration procedure has been developed to use an amorphous silicon flat-panel electronic portal imaging device (EPID) for accurate dosimetric verification of intensity-modulated radiotherapy (IMRT) treatments. Raw EPID images were deconvolved to accurate, high-resolution 2-D distributions of primary fluence using a scatter kernel composed of two elements: a Monte Carlo gen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2019

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(19)32129-2