EP-1735 Dosimetric verification of single isocenter VMAT for multiple brain metastases

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization Algorithm for Single-Isocenter VMAT Stereotactic Radiosurgery for Multiple Brain Metastases

Objectives: Developing an optimal Stereotactic radiosurgery (SRS) plan for multiple brain metastases can be a labor intensive process. Single-isocenter multi-arc volumetrically modulated arc therapy (VMAT) has been used as an SRS technique, in which a Linear Accelerator (Linac) delivers targeted radiation along multiple arc angles as it rotates around the isocenter. Standardized arc angles with...

متن کامل

Dosimetric validation for an automatic brain metastases planning software using single‐isocenter dynamic conformal arcs

An automatic brain-metastases planning (ABMP) software has been installed in our institution. It is dedicated for treating multiple brain metastases with radiosurgery on linear accelerators (linacs) using a single-setup isocenter with noncoplanar dynamic conformal arcs. This study is to validate the calculated absolute dose and dose distribution of ABMP. Three types of measurements were perform...

متن کامل

Dosimetric Study of Automatic Brain Metastases Planning in Comparison with Conventional Multi-Isocenter Dynamic Conformal Arc Therapy and Gamma Knife Radiosurgery for Multiple Brain Metastases

OBJECTIVE The efficacy of stereotactic radiosurgery (SRS) using Gamma Knife (GK) (Elekta, Tokyo) is well known. Recently, Automatic Brain Metastases Planning (ABMP) Element (BrainLAB, Tokyo) for a LINAC-based radiation system was commercially released. It covers multiple off-isocenter targets simultaneously inside a multi-leaf collimator field and enables SRS / stereotactic radiotherapy (SRT) w...

متن کامل

HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach

PURPOSE The HyperArc VMAT (HA-VMAT) planning approach was newly developed to fulfill the demands of dose delivery for brain metastases stereotactic radiosurgery. We compared the dosimetric parameters of the HA-VMAT plan with those of the conventional VMAT (C-VMAT). MATERIAL AND METHODS For 23 patients (1-4 brain metastases), C-VMAT and HA-VMAT plans with a prescription dose of 20-24 Gy were r...

متن کامل

Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases.

BACKGROUND Stereotactic radiosurgery (SRS) is a well-accepted treatment for patients with intracranial metastases, but outcomes with volumetric modulated arc radiosurgery (VMAR) are poorly described. OBJECTIVE To report our initial clinical experience applying a novel single-isocenter technique to frameless VMAR for simultaneous treatment of multiple intracranial metastases. METHODS We perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2019

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(19)32155-3