EP-1811: Dosimetric evaluation of a novel MC dose calculation algorithm for robotic radiosurgery with MLC
نویسندگان
چکیده
منابع مشابه
Effects of static dosimetric leaf gap on MLC‐based small‐beam dose distribution for intensity‐modulated radiosurgery
The aim of the present study was to evaluate the effect of various specific dosimetric leaf gaps on the multileaf collimator (MLC)-based small-beam dose distribution. The dosimetric static leaf gap was determined by comparing the profiles of small MLC-based beams with those of small collimated fields (square fields of 1, 2, 3, and 4 cm). The results showed that an approximately 2-mm gap was opt...
متن کاملDosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
BACKGROUND A study was realised to evaluate and determine relative figures of merit of a new algorithm for photon dose calculation when applied to inhomogeneous media. METHODS The new Acuros XB algorithm implemented in the Varian Eclipse treatment planning system was compared against a Monte Carlo method (VMC++), and the Analytical Anisotropic Algorithm (AAA). The study was carried out in vir...
متن کاملIndependent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.
Independent verification of the MU settings and dose calculation of IMRT treatment plans is an important step in the IMRT quality assurance (QA) procedure. At present, the verification is mainly based on experimental measurements, which are time consuming and labor intensive. Although a few simplified algorithms have recently been proposed for the independent dose (or MU) calculation, head scat...
متن کاملDosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area
Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...
متن کاملA method to improve dose gradient for robotic radiosurgery
For targets with substantial volume, collimators of relatively large size are usually selected to minimize the treatment time in robotic radiosurgery. Their large penumbrae may adversely affect the dose gradient around the target. In this study, we implement and evaluate an inner-shell planning method to increase the dose gradient and reduce dose to normal tissues. Ten patients previously treat...