EP-2244: Accuracy Verification of Dose Calculation Algorithm Based-on TG-43 and AcurosBV on HDR Brachytherapy
نویسندگان
چکیده
منابع مشابه
Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
متن کاملVerification of the accuracy of a photon dose‐calculation algorithm
An extensive set of measured data was developed for the purpose of verifying the accuracy of a photon dose-calculation algorithm. Dose distributions from a linear accelerator were measured using an ion chamber in a water phantom and thermoluminescent dosimeters in a heterogeneous anthropomorphic phantom. Test cases included square fields, rectangular fields, fields having different source-to-su...
متن کاملDetermining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1
Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...
متن کاملthe effects of planning on accuracy and complexity of iranian efl students’ written narrative task performance
this study compared the different effects of form-focused guided planning vs. meaning-focused guided planning on iranian pre-intermediate students’ task performance. the study lasted for three weeks and concentrated on eight english structures. forty five pre-intermediate iranian students were randomly assigned to three groups of guided planning focus-on-form group (gpfg), guided planning focus...
15 صفحه اولthe comparative impact of prompts and recasts in processing instruction versus meaningful output-based instruction on efl learners’ writing accuracy
the purpose of the present study was to see which one of the two instruction-processing instruction (pi) and meaningful output based instruction (mobi) accompanied with prompt and recast- is more effective on efl learners’ writing accuracy. in order to homogenize the participants in term of language proficiency a preliminary english test (pet) was administrated between 74 intermediate students ...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2018
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(18)32553-2