Erosion of Pyrolytic Graphite and Ti-doped Graphite due to High Flux Irradiation
نویسندگان
چکیده
منابع مشابه
Formation and Erosion of Wc under W Irradiation of Graphite
The bombardment of C with 100 keV and 1 MeV W at normal incidence is studied as a function of the incident W fluence experimentally and by computer simulation with the program TRIDYN. Calculated oscillations in the amount of retained W and in the target weight change are confirmed experimentally for 100 keV at room temperature. XPS investigations show W2C formation during ion implantation alrea...
متن کاملCrumpling of a pyrolytic graphite sheet
Crumpled graphite thin film balls were fabricated with Panasonic Pyrolytic Graphite Sheets (PGS). The fractal dimension, mechanical properties, and electrical conductivity of the crumpled PGS balls have been investigated. The universal local fractal dimension of the PGS balls is found to be 2.58, which is consistent with that of paper balls. The crumpled PGS balls show good mechanical property ...
متن کاملPneumoconiosis due to graphite dust.
Lassar Dunner (1945a) recorded the clinical and radiological findings in five men who had been exposed to " pure graphite " dust. They had been exposed for 17, 18, 20, 20, and 34 years respectively, and no other dusts were known to have been implicated. Three of the men had cough, sputum, and dyspnoea; the other two had no complaints. Radiographs showed reticulation with nodulation, and the que...
متن کاملOptical Properties of Pyrolytic Carbon Films Versus Graphite and Graphene
We report a comparative study of optical properties of 5-20 nm thick pyrolytic carbon (PyC) films, graphite, and graphene. The complex dielectric permittivity of PyC is obtained by measuring polarization-sensitive reflectance and transmittance spectra of the PyC films deposited on silica substrate. The Lorentz-Drude model describes well the general features of the optical properties of PyC from...
متن کاملUFM observation of lattice defects in highly oriented pyrolytic graphite
Ultrasonic force microscopy (UFM) can be used to image the distribution of elastic modulus up to several tens of GPa, which is not possible by the force modulation mode using a soft cantilever of spring constant less than 1 N m‘. It was shown that by careful design of a piezoelectric transducer, together with a sample with small friction force, deflection vibration of the cantilever without tor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Nuclear Science and Technology
سال: 1997
ISSN: 0022-3131,1881-1248
DOI: 10.1080/18811248.1997.9733743