Erratum: “Angular truncation errors in integrating nephelometry” [Rev. Sci. Instrum. 74, 3492 (2003)]

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angular truncation errors in integrating nephelometry

Ideal integrating nephelometers integrate light scattered by particles over all directions. However, real nephelometers truncate light scattered in near-forward and near-backward directions below a certain truncation angle ~typically 7°!. This results in truncation errors, with the forward truncation error becoming important for large particles. Truncation errors are commonly calculated using M...

متن کامل

Comment on "MEMS-based high speed scanning probe microscopy" [Rev. Sci. Instrum. 81, 043702 (2010)].

In a recent article, Disseldorp et al. [Rev. Sci. Instrum. 81, 043702 (2010)] present a micromachined z-scanner for scanning probe microscopy (SPM). The scanner comprises a micromachined electrostatically actuated membrane anchored to its substrate with crab-leg flexures. This structure is used as a fast actuator specifically for atomic force microscope and scanning tunneling microscope. The au...

متن کامل

Erratum: "Physical apparatus parameters and model for vibrating tube densimeters at pressures to 140 MPa and temperatures to 473 K" [Rev. Sci. Instrum. 85, 095111 (2014)].

Erratum: “Physical apparatus parameters and model for vibrating tube densimeters at pressures to 140 MPa and temperatures to 473 K” [Rev. Sci. Instrum. 85, 095111 (2014)] Eric F. May,1 Weparn J. Tay,2 Manuela Nania,2 Amos Aleji,2 Saif Al-Ghafri,2 and J. P. Martin Trusler2 1Centre for Energy, School of Mechanical and Chemical Engineering, The University of Western Australia, Crawley, WA 6009, Au...

متن کامل

Comment on "Generation of cold low divergent atomic beam of indium by laser ablation" [Rev. Sci. Instrum. 76, 113302 (2005)].

We present measurements of the velocity distribution of calcium atoms in an atomic beam generated using a dual-stage laser back-ablation apparatus. Distributions are measured using a velocity selective Doppler time-of-flight technique. They are Boltzmann-like with rms velocities corresponding to temperatures above the melting point for calcium. Contrary to a recent report in the literature, thi...

متن کامل

Magnetic resonance imaging using linear magneto-inductive waveguides

Related Articles Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system Appl. Phys. Lett. 90, 114105 (2007) Magnetic resonance-guided near-infrared tomography of the breast Rev. Sci. Instrum. 75, 5262 (2004) Digital imaging processing for biophysical applications Rev. Sci. Instrum. 75, 2822 (2004) Continuous ...

متن کامل