Erratum: ‘‘High power continuous wave atomic Xe laser with radio frequency excitation’’ [Appl. Phys. Lett. 67, 1366 (1995)]

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-frequency, high-power, continuous-wave fiber-laser-pumped Ti:sapphire laser.

We demonstrate a high-power, continuous-wave (cw), single-frequency green source based on single-pass second-harmonic generation of a Yb-fiber laser in MgO:sPPLT as a viable pump source for a cw single-frequency Ti:sapphire ring laser. By careful design and optimization, the Ti:sapphire laser can provide as much as 2.3 W of cw single-frequency output across a 47 nm tuning range, limited by the ...

متن کامل

High-efficiency frequency doubling of continuous-wave laser light.

We report on the observation of high-efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of 95±1%. The latter value is based on the measured depleti...

متن کامل

Continuous-wave broadly tunable high-power Cr:CdS laser

We report spectroscopic characteristics and laser properties of the mid-infrared active laser medium Cr2+:CdS. Temperature-dependent absorption, luminescence and lifetime measurements of the 5E exited state allow determination of peak emission cross section value of 1.35 × 10-18 cm2 in σ-polarization at room temperature. Lifetime values vary from 7.6 µs at 8 K to 0.48 µs at 320 K, corresponding...

متن کامل

Continuous short-wave (radio-frequency) diathermy.

Continuous shortwave diathermy is the technique of choice when uniform marked elevation of temperature is required in the deep tissues. This heating can be targeted accurately by using an appropriate applicator positioned correctly. SWD also allows superficial structures to be heated selectively, although for this the various methods of surface heating are usually preferable. Sub-acute or chron...

متن کامل

Saturation of the Xe III 109-nm laser using traveling-wave laser-produced-plasma excitation.

We describe the construction and operation of a 109-nm, photoionization-pumped, single-pass laser in Xe III. The laser is pumped by soft x rays emitted from a laser-produced plasma in a traveling-wave geometry. Using a 3.5-J, 300-psec, 1064-nm laser pump pulse, we measure a small-signal gain coefficient of 4.4 cm(-1) and a total small-signal gain of exp(40). The laser is fully saturated and pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Physics Letters

سال: 1995

ISSN: 0003-6951,1077-3118

DOI: 10.1063/1.115555