Erratum to: Methodology for commissioning a brachytherapy treatment planning system in the era of 3D planning
نویسندگان
چکیده
منابع مشابه
Commissioning of brachytherapy module of Oncentra MasterPlan treatment planning system
PURPOSE To describe the tests that have been performed in order to commission the Brachytherapy module, version 3.2, service pack 3.0, of the Oncentra MasterPlan treatment plan system (OB), from Nucletron. The results were benchmarked against those obtained with the Plato system, v 14.3.7, also from Nucletron, used in the clinical routine. MATERIAL AND METHODS Commissioning was performed taki...
متن کاملCommissioning For Treatment Planning System
Objective: A process and system of treatment planning is very important in radiation therapy. The features of the software and the accuracy in the dose calculation and dose distribution will affect to the treatment quality as well as the patient outcome. When a treatment planning system is applied in treatment at the first time, it should be checked and approved all its system information, feat...
متن کاملCommissioning of a 3D image‐based treatment planning system for high‐dose‐rate brachytherapy of cervical cancer
The objective of this work is to present commissioning procedures to clinically implement a three-dimensional (3D), image-based, treatment-planning system (TPS) for high-dose-rate (HDR) brachytherapy (BT) for gynecological (GYN) cancer. The physical dimensions of the GYN applicators and their values in the virtual applicator library were varied by 0.4 mm of their nominal values. Reconstruction ...
متن کاملDesign and Implementation of a Complementary Treatment Planning Software for the GZP6 HDR Brachytherapy System (GZP6 CTPS)
Introduction: Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, ...
متن کاملROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system
In this study, the Plaque SimulatorTM eye plaque brachytherapy planning system was commissioned for ROPES eye plaques and Amersham Health model 6711 Iodine 125 seeds, using TG43-UI data. The brachytherapy module of the RADCALC® independent checking program was configured to allow verification of the accuracy of the dose calculated by Plaque SimulatorTM. Central axis depth dose distributions wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Australasian Physical & Engineering Sciences in Medicine
سال: 2010
ISSN: 0158-9938,1879-5447
DOI: 10.1007/s13246-010-0047-z