Transcatheter closure of fontan fenestrations using the Amplatzer septal occluder: initial experience and follow-up.

We have recently used the Amplatzer septal occluder to close Fontan fenestrations. Between June 1998 and December 1999, 13 patients underwent transcatheter occlusion of their Fontan fenestrations. Systemic blood flow decreased significantly without a concomitant decrease in pulmonary blood flow. All residual shunts detectable by oximetry were at sites separate from those into which occlusion de...

متن کامل

Transcatheter closure of secundum atrial septal defects and fenestrated Fontan using the Amplatzer septal occluder. Initial prospective study.

OBJECTIVE To evaluate the safety and efficacy of transcatheter closure of secundum atrial septal defects and fenestrated Fontan with the Amplatzer septal occluder. METHODS Fifteen consecutive patients, with a significant interatrial communications, were considered for the procedure; four patients with defects that were too large or with deficient margins were excluded after initial transesoph...

متن کامل

Transcatheter retrieval of embolized AMPLATZER Septal Occluder.

In selected patients, transcatheter closure of atrial septal defects with the AMPLATZER Septal Occluder has yielded excellent results. However, there is a slight risk of device embolization after deployment. We report the case of a 26-year-old woman in whom an embolized AMPLATZER device was retrieved percutaneously from the right pulmonary artery. We also discuss important technical principles ...

متن کامل

Amplatzer septal occluder-induced transient complete atrioventricular block.

Percutaneous transcatheter atrial septal defect (ASD) closure is a widely used technique that has replaced open-heart surgical closure in many centers. The most common implant is the Amplatzer septal occluder which seems to be a highly effective and safe device. However, there are reports of complications associated with its implantation. We report a 9-year-old boy who presented with complete a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The International Journal of Cardiovascular Imaging

سال: 2011

ISSN: 1569-5794,1573-0743

DOI: 10.1007/s10554-010-9765-2