Erratum: ``Ultrasonic Absorption in Sodium Acetate Solution''

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonic investigation of amino acids in aqueous sodium acetate medium

The ultrasonic velocity (U), density ( ρ) and viscosity (η) measurements have been carried out for four amino acids namely L-alanine, L-leucine, L-valine and L-proline in aqueous sodium acetate solution as a function of composition at 303, 308 and 313K. Experimental data have been used to estimate the adiabatic compressibility (β), change in adiabatic compressibility (∆β), relative change in ad...

متن کامل

Absorption of 193- and 213-nm laser wavelengths in sodium chloride solution and balanced salt solution.

OBJECTIVE To determine absorption coefficients for sodium chloride solution (saline) and balanced salt solution at the 193- and 213-nm laser wavelengths. METHODS Absorption coefficients were obtained for each of the component species found in balanced salt solution. This was achieved by measuring laser pulse transmission through solutions of varying concentration. The experiments were repeate...

متن کامل

Ultrasonic Absorption Microscope

This paper constitutes a progress rersort on the develol•ment of an ultrasonic instrument for detecting microstructure. The principle of operation of the device (designated by the term "ultrasonic microscope") is as follows: The specimen is imbedded in a liquid, which closely matches it in acoustic impedance, and is irradiated with sho•t pulses of highdreqnency hound. Some of the ultrasonic ene...

متن کامل

Ultrasonic absorption and attenuation in mammalian tissues.

-The ultrasonic absorption was determined, by the transient thermoelectric method, for brain, heart, kidney, liver, tendon, and testis from cat, mouse, pig and beef. Comparison of these absorption {a) values with published values of attenuation (A) shows: (1) that the a and A coefficients have nearly the same frequency dependencies in the range 0.5-7 MHz, (2) that the magnitudes of a and A diff...

متن کامل

Acetate absorption and metabolism in the rabbit

Acetate disappearance from the loops of the hindgut in the rabbit was evaluated by measuring variations in the concentration of acetate in caecocolonic loops and differences in the arterial and venous plasma. In vivo metabolism in gut and liver tissues was studied after introduction of (1-'4C) acetate into caecocolonic loops. The rate of disappearance from the loops was quantitatively significa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Chemical Physics

سال: 1967

ISSN: 0021-9606,1089-7690

DOI: 10.1063/1.1840809