Estimated cardiac output and cardiovascular profile score in fetuses with high cardiac output lesions

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vein of Galen Aneurysmal Malformation and High-output Cardiac Failure in a Newborn

Background: Vein of Galen aneurysm (VGA) is the most common form of symptomatic cerebrovascular malformation in neonates. It develops in a fetus in the first trimester of pregnancy due to unknown reasons, but it is likely to have a genetic etiology. The prognosis of VGA is usually poor, particularly in newborns with heart failure due to high-flow intracerebral shunt. Surgery and endovascular em...

متن کامل

Cardiac Output

of time the influence of matter on life and mind will gradually become obliterated and replaced by the influence of mind and its transcendent successors in the great steps of creative evolution." Therefore, "the remote successors of man may be free and independent of matter with infinite possibilities of future progress notwithstanding the complete dissolution of the universe." Pure thought, th...

متن کامل

Normal and High Cardiac Output Borderline Hypertension

30. Spann JR Jr, Mason DT, Zelis RF: The altered performance of the hypertrophied and failing heart. Am J Med Sci 258: 291, 1969 31. Mehmel HC, Mazzoni S, Krayenbuehl HP: Contractility of the hypertrophied human left ventricle in chronic pressure and volume overload. Am Heart J 90: 236, 1975 32. Williams JF Jr, Potter RD: Normal contractile state of hypertrophied myocardium after pulmonary arte...

متن کامل

A Novel ±0.5V Ultra High Current Drive and Output Voltage Headroom Current Output Stage with Very High Output Impedance

A novel ultra-high compliance, low power, very accurate and high output impedance current output stage (COS) with extremely high output current drive capability is proposed in this paper. The principle of operation of this unique structure is discussed, its most important formulas are derived and its outstanding performance is verified by HSPICE simulation in TSMC 0.18µm CMOS, BSIM3, and Level4...

متن کامل

Endotracheal cardiac output monitor.

BACKGROUND The endotracheal cardiac output monitor (ECOM) is a new device that uses an endotracheal tube with multiple electrodes to measure cardiac output (CO). It measures the changes in electrical impedance caused by pulsatile blood flow in the aorta. The system was tested for safety and efficacy in 10 swine. METHODS Swine (60-80 kg) were chronically instrumented with a transit time flow p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ultrasound in Obstetrics & Gynecology

سال: 2012

ISSN: 0960-7692

DOI: 10.1002/uog.12309