Estimation of Exposure Dose from CBCT for Prostate IMRT and Approach to Reduce Local Exposure Dose
نویسندگان
چکیده
منابع مشابه
Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation
Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that c...
متن کاملAssessment of Effective Dose Equivalent from Internal Exposure to 222Rn in Ramsar City
Introduction In this study, effective dose equivalent for the public due to internal exposure to 222radon (222Rn) was evaluated in three regions of Ramsar, a northern coastal city in Iran. Materials and Methods Measurements were carried out using a radon monitoring device. Outdoor and indoor radon concentrations were measured within 24 hours with an integration in...
متن کاملEstimation of radiation dose of emergency exposure during the hospitalized 131I therapy patient
Background: The aim of the study was to estimate the radiation dose during emergency exposure to patients treated with iodine-131 during the isolation period. Materials and Methods: The dose rate from a sample of 192 patients administrated by three different radioactivity of 131I (3.7, 5.55 and 7.4 GBq) was measured, at 1 meter after 1, 24 and 48 hours post dose administration, at three d...
متن کاملExposure and organ dose estimation in diagnostic radiology.
This paper discusses a methodology which uses a specially developed computer program that enables estimation of output parameters of an x-ray machine from a single test exposure. Exposure at skin entrance values can be estimated, as well as using the data from the program for organ dose estimates. To perform the estimation procedure, curves and analytical expressions for the curves are presente...
متن کاملEffects of exposure imprecision on estimation of the benchmark dose.
In regression analysis failure to adjust for imprecision in the exposure variable is likely to lead to underestimation of the exposure effect. However, the consequences of exposure error for determination of safe doses of toxic substances have so far not received much attention. The benchmark approach is one of the most widely used methods for development of exposure limits. An important advant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 2011
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.67.183