Estimation of Split Renal Function With 99mTc-DMSA SPECT: Comparison Between 3D Volumetric Assessment and 2D Coronal Projection Imaging

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

متن کامل

Reproducibility of renal length measurements with 99mTc-DMSA SPECT.

UNLABELLED Renal length measurements are used in evaluating several abnormalities of the pediatric genitourinary tract. This study assesses reproducibility of renal length measurements obtained with 99mTc-dimercaptosuccinic acid (DMSA) SPECT. METHODS The lengths of 98 kidneys of 51 children (age range, 1-16 y; mean age, 5.4 y) who underwent 99mTc-DMSA SPECT were measured independently by 2 ob...

متن کامل

the comparison between ultrasonography and 99mtc-dmsa renal scan in estimation of kidney size

introduction: renal length measurement is an important diagnostic clue in several urinary tract abnormalities. although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mtc-dmsa scintigraphy is of great value. by now, pointing to the renal size in the 99mtc-dmsa scintigraphy report has not been recommended by guidelines. if the validi...

متن کامل

Comparison of IVP-simulator and 99mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]

To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used 99mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was 81.88 in right and ...

متن کامل

Comparison of relative renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured with 99mTc-DMSA static scintigraphy.

OBJECTIVE The aim of this study was to compare the renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured using 99mTc-DMSA static scintigraphy. METHODS the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99mTc-DTPA (55 studies) or with 99mTc-EC (56 studies) were compared with the relative functi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: American Journal of Roentgenology

سال: 2016

ISSN: 0361-803X,1546-3141

DOI: 10.2214/ajr.16.16307