Eurocode 1-6 in buckling calculation of agricultural steel silos
نویسندگان
چکیده
منابع مشابه
Assessment of Eurocode 5 Charring Rate Calculation Methods
The basic hypothesis for the assessment of fire resistance of wood structures is that for temperatures above 300 oC, wood is no longer able to sustain any load. Consequently, the determination of the location of the 300 oC isotherm, the charring depth, is decisive for the result of fire resistance calculation methods. Charring rate of wood is dependent of numerous factors, such as wood species ...
متن کاملFuzzy Probability Methods in Applications to Reliability Analysis of Eurocode Rules for Steel Structure Design
The topic of the paper is the probabilistic analysis of the ultimate limit state of a steel strut loaded by permanent and long-time single variation action. The failure probability misalignment according to the EN 1990 concept of a structure designed according to the EUROCODE 3 is analyzed here. In the stochastic model, material and geometrical characteristics of a hot-rolled steel cross-sectio...
متن کاملLocal and Distortional Buckling of Cold-Formed Steel Members
Laminar structures have a high post-buckling strength reserve. Cold-formed steel profiles can be taken as a set of thin plate elements. Therefore it is necessary to design this type of profiles taking into account that reserve of strength in post-local buckling modes of failure. The method normally used to design this type of structures is based on the Effective Width concept. The Effective Wid...
متن کاملnon-linear study of various slit shear walls in steel structures
seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...
15 صفحه اولDistortional Buckling Tests on Cold-Formed Steel Beams
Failure in cold-formed steel beams is generally initiated by one of three instabilities: local, distortional, or lateral-torsional buckling. For cold-formed steel joists, purlins, or girts, when the compression flange is not restrained by attachment to sheathing or paneling, distortional buckling may be the predominant failure mode. Experimental results on cold-formed steel beams with unrestrai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Informes de la Construcción
سال: 2002
ISSN: 1988-3234,0020-0883
DOI: 10.3989/ic.2002.v54.i480.610