Europium Determination In Some Rare Earth Elements by Isotope Dilution Method
نویسندگان
چکیده
منابع مشابه
Tubulin Determination by an Isotope Dilution-vinblastine Precipitation Method
BETH BURNSIDE, CHRIS KOZAK, and F. C. KAFATOS. From the Marine Biological Laboratory, Woods Hole, Massachusetts 02543 . Dr . Burnside's present address is the Department of Anatomy, School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 . Dr . Kozak's present address is the Department of Biology, Yale University, New Haven, Connecticut 06520 . Dr. Kafatos' present addr...
متن کاملRare Earth Elements Profile
Definitions and characteristics The rare earth elements (REE) (sometimes referred to as the rare earth metals) are a group of 17 chemically similar metallic elements, including the 15 lanthanides, scandium and yttrium. The lanthanides are elements spanning atomic numbers 57 (lanthanum, La) to 71 (lutetium, Lu) (Table 1). The lanthanides all occur in nature, although promethium, the rarest, only...
متن کاملX-ray fluorescence analysis of rare earth elements in rocks using low dilution glass beads.
Major and trace elements (Na, Mg, Al, Si, P, K, Ca, Ti, Mn, Fe, Rb, Sr, Y, Zr, La, Ce, Pr, Nd, Sm, Gd, Dy, Th and U) in igneous rocks were assayed with fused lithium borate glass beads using X-ray fluorescence spectrometry. Low dilution glass beads, which had a 1:1 sample-to-flux ratio, were prepared for determination of rare earth elements. Complete vitrification of 1:1 mixture required heatin...
متن کاملStudy on Fluorescence Intensity Determination of Rare Earth Europium Complexes UV-Photochromic Inks
The paper discussed the preparation of rare earth europium complexes ultraviolet rays (UV) photochromic ink and the influences of factors, such as europium complexes using a rare earth ternary complex of Eu ion with 3-benzoylbenzoic acid and phenathrolinephen [Eu(BA)3Phen] content upon printing ink formula. In the experiment, we utilized fluorescence spectrophotometer to make quantitative deter...
متن کاملDetermination of serum glucose by isotope dilution mass spectrometry: candidate definitive method.
We report a rather simple method to determine glucose concentration in serum, using isotope dilution mass spectrometry and [13C6]glucose as internal standard. The procedure involves a single step of sample purification and the conversion of the analyte into its aldononitrile pentaacetate. The between-day and within-day contribution to total variance for a single measurement was determined by as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Mass Spectrometry Society of Japan
سال: 1961
ISSN: 1884-3271,1340-8097
DOI: 10.5702/massspec1953.9.161