Evaluation and Mitigation of Voltage and Current Unbalance at MSTP Undip Jepara

نویسندگان

چکیده

Abstract Marine Science Techno Park (MSTP) Diponegoro University is a central for the application of technology and research in fisheries marine sector under auspices University. After measuring electrical power quality parameters, voltage current unbalance problem was found on each SDP MDP at MSTP Undip Jepara Building. The final project designed to mitigate with load equalization method phase using ETAP 12.6 software. According ANSI C84.1-1995 standard, maximum value 5% according IEEE 45-2002 3%. results show that can decrease unbalance, neutral already meets standards. Based evaluation existing conditions, decreased from 21.522% 0.419%, bus 0.280% 0.015%, 35.5 ampere 1 ampere.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and volt...

متن کامل

Voltage Unbalance Mitigation Using Positive Sequence Series Compensator

Voltage Unbalance is a common type of power quality problem. Sequence components occur during unbalance in three phase system. For this reason unbalance is assessed with respect to the sequence components present in the system. Voltage unbalance may adversely affect power system components connected to the system. In this paper, for symmetric and asymmetric faults, positive sequence voltage is ...

متن کامل

Effect of Voltage Unbalance on Adjustable Speed Drives and its Mitigation Using Supercapacitor

During the voltage unbalance, the resulting adverse effects on equipments such as induction motors and power electronic converters and drives on ASDs have been described. It has been observed that during unsymmetrical fault, the input rectifier slips into the single phase operation and draw heavy currents which may actuate the overload protection and trip the ASDs. The application of supercapac...

متن کامل

Battery energy storage system for peak shaving and voltage unbalance mitigation

Over the last decade, the battery energy storage system (BESS) has become one of the important components in smart grid for enhancing power system performance and reliability. This paper presents a strategy to shave the peak demand and mitigate the voltage unbalance of the electrical networks using a BESS. The BESS is developed to reduce the peak demand and consequently the electricity bill of ...

متن کامل

hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures

شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2406/1/012013