Evaluation of a biplanar diode array dosimeter for quality assurance of step-and-shoot IMRT

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a biplanar diode array dosimeter for quality assurance of step‐and‐shoot IMRT

In this paper, we described and characterized a novel biplanar diode array, and demonstrated its applicability to dosimetric QA of the step-and-shoot IMRT. It is the first commercially available device of its kind specifically designed for measurements at varying gantry angles. The detector consists of a cylindrical PMMA phantom with two orthogonal detector boards. There are a total of 1069 p-t...

متن کامل

Evaluation of a 2D diode array for IMRT quality assurance.

BACKGROUND AND PURPOSE The QA of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida) and assess the role it can play in routine IMRT QA. MATERIAL AND METHODS Fundamental properties of the MapCheck such as reproducibility, li...

متن کامل

Clinical implications of the overshoot effect for treatment plan delivery and patient‐specific quality assurance for step‐and‐shoot IMRT

In this work, overshoot and undershoot effects associated with step-and-shoot IMRT (SSIMRT) delivery on a Varian Clinac 21iX are investigated, and their impact on patient-specific QA point dose measurements and treatment plan delivery are evaluated. Pinnacle3 SSIMRT plans consisting of 5, 10, and 15 identical 5 × 5 cm2 MLC defined segments and MU/segment values of 5 MU, 10 MU, and 20 MU were ut...

متن کامل

Evaluation of a 3D diode array dosimeter for helical tomotherapy delivery QA.

The Delta4 biplanar diode array dosimeter was validated for helical tomotherapy delivery QA. The basic detector characteristics were found to be satisfactory in terms of short-term reproducibility (0.1%), linearity (<0.1%), dose rate dependence (0.4%), and absolute calibration accuracy (0.4% in the center of the phantom compared with the independently calibrated diode). Relative calibration of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2009

ISSN: 1526-9914

DOI: 10.1120/jacmp.v10i4.3080