Evaluation of a metal artifacts reduction algorithm applied to postinterventional flat panel detector CT imaging.

BACKGROUND AND PURPOSE Flat panel detector CT images are degraded by streak artifacts caused by radiodense implanted materials such as coils or clips. A new metal artifacts reduction prototype algorithm has been used to minimize these artifacts. The application of this new metal artifacts reduction algorithm was evaluated for flat panel detector CT imaging performed in a routine clinical settin...

متن کامل

Evaluation of the quality of CT-like images obtained using a commercial flat panel detector system

PURPOSE The development of flat panel detector technology has resulted in renewed interest in the possibility of generating CT-like images from rotational angiographic acquisitions. At least two commercial products now use cone beam reconstruction software in conjunction with flat panel detectors to produce such images. The purpose of the work presented here is to report on image quality obtain...

متن کامل

Transcranial access using fluoroscopic flat panel detector CT navigation.

FPCT and navigation software on contemporary fluoroscopic units perform imaging of a quality comparable with conventional CT. They can accurately guide percutaneous procedures, providing live instrument visualization and the capability to re-image without patient transfer. FPCT navigation was used in the placement of a ventricular drain in a 62-year-old woman for subarachnoid-related hydrocepha...

متن کامل

Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Flat-panel-detector x-ray cone-beam computed tomography (CBCT) is used in a rapidly increasing host of imaging applications, including image-guided surgery and radiotherapy. The purpose of the work is to investigate and evaluate image reconstruction from data collected at projection views significantly fewer than what is used in current CBCT imaging. Specifically, we carried out imaging experim...

متن کامل

Neuroradiologic applications with routine C-arm flat panel detector CT: evaluation of patient dose measurements.

BACKGROUND AND PURPOSE Since the introduction of flat panel detector-equipped C-arms, the use of flat panel detector CT (FPCT) in the neuroradiologic angiography suite has become more frequent. This examination implicates its own specific radiation exposure. We used the CT dose index (CTDI) concept and adapted it to the special FPCT geometry to provide a consistent comparison with multisection ...