Evaluation of a wind power parameterization using tower observations

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a Wind Power Parameterization Using Tower Observations

The spatial and temporal components of a published wind power parameterization method are evaluated using observed winds (9 m to 90 m) from 7 years of data collected at 4 towers in the Kennedy Space Center/Cape Canaveral Air Force Station network. The temporal component is governed by two parameterization inputs which represent the amplitude and mean of an assumed sinusoidal diurnal variation o...

متن کامل

Evaluation of a GCM cirrus parameterization using satellite observations

This study applies a simple yet effective methodology to validate a general circulation model parameterization of cirrus ice water path. The methodology combines large-scale dynamic and thermodynamic fields from operational analyses with prescribed occurrence of cirrus clouds from satellite observations to simulate a global distribution of ice water path. The predicted cloud properties are then...

متن کامل

Reply (Evaluation of Land-Surface Parameterization Schemes Using Observations)

Robock et al. (1995a) tested a 15-cm bucket model (Manabe 1969) and the Simplified Simple Biosphere (SSiB) model (Xue et al. 1991) by forcing them with observed meteorological and actinometric data and comparing the results with observed soil moisture, albedo, snow depth, and net radiation. Xue et al. (1997) show that it is possible to improve SSiB in response to errors in the simulations by fi...

متن کامل

Wind Turbine Tower Resonance

Wind turbine towers are large structures designed to withstand the unique loading conditions imposed on them by the turbine’s nacelle and dynamic forces from the rotating blades. Observations and noise measurements of a particular wind turbine showed high noise levels at approximately 48 Hz, which could not be explained from the usual known potential noise sources. Correlated far field noise me...

متن کامل

Evaluation of global wind power

[1] The goal of this study is to quantify the world’s wind power potential for the first time from data. Wind speeds are calculated at 80 m, the hub height of modern, 77-m diameter, 1500 kW turbines. Since relatively few observations are available at 80 m, the Least Square extrapolation technique is utilized and revised here to obtain estimates of wind speeds at 80 m given observed wind speeds ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Geophysical Research

سال: 2005

ISSN: 0148-0227

DOI: 10.1029/2004jd005614