Evaluation of an Arsenic Test Kit for Rapid Well Screening in Bangladesh

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an arsenic test kit for rapid well screening in Bangladesh.

Exposure to arsenic in groundwater via drinking remains unabated for millions of villagers in Bangladesh. Since a blanket testing campaign using test kits almost a decade ago, millions of new wells have been installed but not tested; thus affordable testing is needed. The performance of the Arsenic Econo-Quick (EQ) kit was evaluated by blindly testing 123 wells in Bangladesh and comparing with ...

متن کامل

Comment on "Reliability of a commercial kit to test groundwater for arsenic in Bangladesh".

In a recent publication, “Reliability of a commercial kit to test groundwater for arsenic in Bangladesh” (1) regarding the effectiveness of the Hach EZ arsenic kit (product 2822800), Van Geen et al. remarked “Clearly the Hach kit should continue to be used to test wells throughout Bangladesh and other countries affected by elevated arsenic in groundwater”. They studied only 799 wells in a 25-sq...

متن کامل

Reliability of a commercial kit to test groundwater for arsenic in Bangladesh.

A comparison of field and laboratory measurements of arsenic in groundwater of Araihazar, Bangladesh, indicates that the most widely used field kit correctly determined the status of 88% of 799 wells relative to the local standard of 50 microg/L As. Additional tests showthatthe inconsistencies, mainly underestimates in the 50-100 microg/L As range, can be avoided by increasing the reaction time...

متن کامل

Evaluation of NCS rapid plasma reagin card test, a new screening kit for syphilis.

Agreements in qualitative and quantitative test results between the recently marketed NCS rapid plasma reagin card test (NCS Diagnostics Corp.) and the Macro-Vue rapid plasma reagin 18-mm circle card test (Hynson, Westcott and Dunning) were 99.2 and 99.1%, respectively, indicating the NCS RPR card test to be an acceptable alternative procedure for the serodiagnosis of syphilis.

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Environmental Science & Technology

سال: 2012

ISSN: 0013-936X,1520-5851

DOI: 10.1021/es300253p