Evaluation of Cell Viability Using Terahertz Attenuated Total Reflection Spectroscopy
نویسندگان
چکیده
منابع مشابه
Attenuated internal reflection terahertz imaging.
We present a terahertz (THz) imaging technique based on attenuated internal reflection, which is ideally suited for the analysis of liquid and biological samples. Inserted in a THz time-domain system, and using a high-resistivity low loss silicon prism to couple the THz wave into the sample, the detection scheme is based on the relative differential spectral phase of two orthogonal polarization...
متن کاملDetection of Ni2+ by a dimethylglyoxime probe using attenuated total-reflection infrared spectroscopy.
A new analytical approach for the detection of Ni2+ utilizing an attenuated total reflection (ATR) technique is discussed in this paper. Nickel detection was accomplished on a silicon ATR parallelogram crystal uniformly coated by a ca. 1.5-microm Nafion film embedded with dimethylglyoxime (DMG) probe molecules. The detection of Ni2+ is based on the appearance of a unique infrared absorption pea...
متن کاملWet-Chemical Treatment of Si3N4 Surfaces Studied Using Infrared Attenuated Total Reflection Spectroscopy
Same as Report (SAR) 18. NUMBER
متن کاملRapid determination of total trans fat content--an attenuated total reflection infrared spectroscopy international collaborative study.
Interest in trans fat labeling has prompted efforts to develop new, more efficient methods for rapidly and accurately determining trans fat content of foods. A novel and rapid (5 min) attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopic procedure was recently developed and applied to food products. This procedure was voted official method AOCS Cd 14d-99 by the America...
متن کاملSingle-reflection attenuated total reflection of organic monolayers on silicon.
Attenuated total re ection (ATR) spectroscopy, a wellknown surface technique, is frequently used for examining very thin lms on substrates. However, when it comes to examining thin lms on silicon substrates, the high refractive index of the substrates seems to preclude ATR analysis. This paper demonstrates that extraordinary sensitivity can be achieved by using ATR to analyze monolayers on...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Society of Instrument and Control Engineers
سال: 2013
ISSN: 0453-4654,1883-8189
DOI: 10.9746/sicetr.49.197