Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer.
PURPOSE The Ocular Response Analyzer (ORA) is a new instrument that measures the corneal biomechanical response (corneal hysteresis, CH) to rapid indentation by an air jet. CH is the difference in applanation pressures (P1, P2) between the rising and falling phases of the air jet. The investigation had two parts: a characterization study and a validation study. In the characterization study, th...
متن کاملevaluation of corneal biomechanical properties following scleral buckling using the ocular response analyzer
purpose : to evaluate corneal visco-elasticity and intraocular pressure (iop) changes measured by an ocular response analyzer (ora) after scleral buckling methods : fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. corneal hysteresis (ch), corneal resistance factor (crf), corneal-compensated iop (iopcc) and goldmann-correlated iop (iopg) were m...
متن کاملCorneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer
Purpose. To evaluate the corneal biomechanical parameters in myopic and emmetropic eyes using Corneal Visualization Scheimpflug Technology (CorVis ST). Methods. 103 myopic and emmetropic eyes of 103 patients were examined. Corneal biomechanical parameters, axial length, and mean keratometry were measured using CorVis ST, IOL Master, and topography, respectively. Corneal biomechanical properties...
متن کاملBiomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
BACKGROUND To evaluate the relationships between Reichert Ocular Response Analyzer (ORA) parameters corneal hysteresis (CH) and corneal response factor (CRF) and ocular dimensions, age and intraocular pressure. METHODS Two hundred and twelve eyes of 212 participants with no ocular pathology had CH and CRF measured with the ORA. Intraocular pressure (IOP) was measured with the Dynamic Contour ...
متن کاملCorneal hysteresis measured with the Ocular Response Analyzer in normal and glaucomatous eyes.
PURPOSE To identify differences in corneal hysteresis (CH) and central corneal thickness (CCT) between healthy and glaucomatous patients. METHODS Retrospective observational study. One hundred and thirty-three eyes of 75 healthy and 58 glaucomatous patients were included. CH was measured in each patient using Ocular Response Analyzer. CCT was determined by ultrasonic pachymetry. For each pati...