Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at...

متن کامل

Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients

PURPOSE To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients. DESIGN Retrospective comparative case series. METHODS This was a comparative case series of 36 eyes of 36 African Americans and 43 eyes of 43 whites that underwent placement of the Ex-PRESS glaucoma filtration device under a partial-thickness scleral flap for ...

متن کامل

Screening of CYP1B1 Arg368His as predominant mutation in North Indian primary open angle glaucoma and juvenile onset glaucoma patients

In India, mutations in Cytochrome P450 (CYP1B1) are a predominant cause of not only primary congenital glaucoma (PCG) but also involved in primary open angle glaucoma (POAG) and juvenile onset glaucoma (JOAG). After ethical clearance, 100 POAG patients, 30 primary angle closure glaucoma (PACG) patients and 130 ethnically matched controls were recruited in this study. Genomic DNA was is...

متن کامل

Depression and Quality of Life in Patients with Glaucoma

Purpose: To investigate the frequency of depression and quality of life in patients with glaucoma. Methods: This cross-sectional study included 204 patients (102 males and 102 females) with a mean age of 58.9±11.96 and a range of 40 to 85 years old. Achromatic perimetry was performed, using the HFA SITA-standard 24-2. Severity was stratified according to the Nelson Glaucoma Severity Scale (base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian Journal of Ophthalmology

سال: 2015

ISSN: 0301-4738

DOI: 10.4103/0301-4738.159894