Evaluation of Initial Fixation Using Isthmus-guided Cortical Bone Trajectory (CBT) Technique

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiological Evaluation of the Initial Fixation between Cortical Bone Trajectory and Conventional Pedicle Screw Technique for Lumbar Degenerative Spondylolisthesis

STUDY DESIGN Retrospective study. PURPOSE To compare initial fixation using the cortical bone trajectory (CBT) technique versus conventional pedicle screws (PS) in radiographs of postsurgical lumbar degenerative spondylolisthesis. OVERVIEW OF LITERATURE Few reports have documented the holding strength of CBT technique for spondylolisthesis cases. METHODS From October 2009 to June 2014, 21...

متن کامل

Review of Cortical Bone Trajectory: Evidence of a New Technique

This article summarizes recent evidence on the cortical bone trajectory (CBT) obtained from published anatomical, biomechanical, and clinical studies. CBT was proposed by Santoni in 2009 as a new trajectory that can improve the fixation of pedicle screws in response to screw loosening in osteoporotic patients. Recently, research interest has been growing with increasing numbers of published ser...

متن کامل

The "medio-latero-superior trajectory technique": an alternative cortical trajectory for pedicle fixation.

An alternative pedicle trajectory for use at the superior end of a construct to limit dissection of the mobile superior facet joint and reduce incision length and muscle dissection, thus minimizing approach-related trauma during pedicle fixation, is reported. The medio-latero-superior trajectory technique involves a starting point on the medial aspect of the pars and angulation of the pedicle s...

متن کامل

Erratum to: A biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation

Erratum After publication of the original article [1] it came to our attention that the legends for figures 2 and 3 had been interchanged. The correct legend for figure two is 'Pedicle screw fusion model' and the correct legend for figure three is 'Cortical bone trajectory model'. biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation. permits unrestricted...

متن کامل

A biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation

PURPOSE There have been several reports on the pullout strength of cortical bone trajectory (CBT) screws, but only one study has reviewed the stability of functional spine units using the CBT method. The purpose of this study was to compare vertebral stability after CBT fixation with that after pedicle screw (PS) fixation. METHODS In this study, 20 lumbar spine (L5-6) specimens were assigned ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Spinal Surgery

سال: 2015

ISSN: 0914-6024,1880-9359

DOI: 10.2531/spinalsurg.29.334