Evaluation of Resistane Exercise-Induced Muscle Swelling Using Bioelectrical Impedance Analysis
نویسندگان
چکیده
منابع مشابه
Bioelectrical impedance analysis revisited.
Although total limb volume measurements are used to track the progress of lymphedema and its treatment, these measurements can be confounded by changes other than fluid excess namely muscle or fat gain. Bioelectrical impedance analysis (BIA) is a technique that specifically quantifies both total body fluid and extracellular fluid in extremities. Whereas BIA has potential as a quick, inexpensive...
متن کاملEstimation of skeletal muscle mass by bioelectrical impedance analysis.
The purpose of this study was to develop and cross-validate predictive equations for estimating skeletal muscle (SM) mass using bioelectrical impedance analysis (BIA). Whole body SM mass, determined by magnetic resonance imaging, was compared with BIA measurements in a multiethnic sample of 388 men and women, aged 18-86 yr, at two different laboratories. Within each laboratory, equations for pr...
متن کاملEvaluation of lymph drainage using bioelectrical impedance of the body.
AIM The aim of this study was to investigate the effects of manual and mechanical lymph drainage on the bioelectrical composition of body tissues of patients with lymphoedema of the lower limbs. METHOD Twenty-one patients with lymphoedema of one leg were evaluated using single frequency bioelectrical impedance with four electrodes (SF-BIA4) immediately before and after a combination of manual...
متن کاملValidity of using multi-frequency bioelectrical impedance analysis to measure skeletal muscle mass in preschool children
[Purposes] Although it is recommended to develop a habit of physical activities, there is no easy way to measure skeletal muscle mass in preschool children, which cause the difficulty of evaluation. The purpose of this study was to examine the validity of body composition including the skeletal muscle mass assessment using multi-frequency bioelectrical impedance analysis by comparing body fat m...
متن کاملEvaluation of body composition in COPD patients using multifrequency bioelectrical impedance analysis
BACKGROUND Multifrequency bioelectrical impedance analysis (MF-BIA) is a technique that measures body impedance (Z) at different frequencies (5, 10, 50, 100, and 250 kHz). Body composition may be estimated using empirical equations, which include BIA variables or, alternatively, raw BIA data may provide direct information on water distribution and muscle quality. OBJECTIVES To compare raw MF-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medicine & Science in Sports & Exercise
سال: 2019
ISSN: 1530-0315,0195-9131
DOI: 10.1249/01.mss.0000561516.37072.8c