Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

PURPOSE The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. Th...

متن کامل

Prosthetic laboratory influence on the vertical misfit at the implant/UCLA abutment interface.

An inadequate fit at the abutment/implant interface can generate mechanical and biological problems. The laboratorial stages could induce misfit in such interface when the castable UCLA abutment type is used. The purpose of this study was to comparatively evaluate the performance of three prosthetic laboratories (Labs A, B and C) by vertical fit analysis of castable UCLA abutments on the castin...

متن کامل

Effect of Casting Procedure on Screw Loosening of Ucla Abutment in Two Implant-abutment Connection Systems

Since Bra�nemark et al published the results of a 10-year study on osseointegration in 1977, dental implants have increasingly been used to replace missing teeth. The use of osseointegrated implants had become a successful procedure for the treatment of complete, partial edentulism, and single-tooth replacements in both the anterior and posterior regions of the mouth. Although improvements in m...

متن کامل

Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique

OBJECTIVES Microbial leakage through the implant-abutment (I-A) interface results in bacterial colonization in two-piece implants. The aim of this study was to compare microleakage rates in three types of Replace abutments namely Snappy, GoldAdapt, and customized ceramic using radiotracing. MATERIALS AND METHODS Three groups, one for each abutment type, of five implants and one positive and o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Advanced Prosthodontics

سال: 2016

ISSN: 2005-7806,2005-7814

DOI: 10.4047/jap.2016.8.6.465