Evolution of Elements on Electrode Surfaces in Gas-Insulated Systems under Electrical Heating
نویسندگان
چکیده
Accidents always occur in gas-insulated switchgears (GIS) and lines (GIL) since filmed joint electrodes are produced when internal gases react with the electrode’s surface there is a discharge or electricals overheat. To solve problem, this paper analyzed evolution of elements on contact electrode. The reaction SF6 under breakdown currents overheating conditions was obtained, time current effects upon transfer element were proposed. It found that mobility F typically increases after electrical heating. number interruptions short-circuit important factors affecting to flashover essential factor accelerates insulating materials. Frequent switching main contact. also Al has little correlations breaking process, metal fluorides become components research provides theoretical basis data support for GIS/GIL optimization treatments improvement fault detection methods.
منابع مشابه
Hydrogen evolution by cobalt tetraimine catalysts adsorbed on electrode surfaces.
Aryl-substituted tetraimine complexes related to Co(dmgBF(2))(2)(MeCN)(2) (dmg = dimethylglyoxime) were synthesized and are active for hydrogen evolution. Co(dmgBF(2))(2)(MeCN)(2) can be adsorbed to a glassy carbon electrode. The chemically modified electrode is active for hydrogen evolution in aqueous solution at pH < 4.5, with an overpotential of only 100 mV.
متن کاملAnalysis of effective factors on transient ground potential rise in gas insulated substations
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10μs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and problem...
متن کاملMulti-electrode systems for electrical impedance tomography.
A wide range of electrode system designs is reviewed for their possible use in UT
متن کاملAnalysis of effective factors on transient ground potential rise in gas insulated substations
This study presents the manner in which transient modeling concepts, which are fully analyzed in the referred standards, are implemented, for the purpose of evaluating the Transient Ground Potential Rise (TGPR). This is a phenomenon of 10–100kV voltages with up to 10µs duration on the grounded enclosure of Gas Insulated Substations (GIS), which may cause concern for personnel safety and pro...
متن کاملDetection in Spacer of Gas-Insulated Switchgears
With the increasing demand for precise condition monitoring and diagnosis of 11 gas-insulated switchgears (GIS), it has become a challenge to improve the detection sensitivity of 12 partial discharge (PD) induced in the GIS spacer. This paper deals with the elimination of the 13 capacitive component from the phase resolved partial discharge (PRPD) signal generated in GIS 14 spacer based on the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Coatings
سال: 2022
ISSN: ['2079-6412']
DOI: https://doi.org/10.3390/coatings13010033